DFNT ProLinx Gateway Reference
EtherNet/IP Explicit Messaging Client/Server Protocol Manual
ProSoft Technology, Inc. Page 113 of 124
July 24, 2013
The TARGET DEVICE DATA TABLE ADDRESS must be set to a valid file element
(such as, N11:0) for SLC and PLC5 messages. For the PLC2 Unprotected Read
message, set the address to the database index (such as, 1000) to consider with
the command.
The MULTIHOP option must be set to YES. The MULTIHOP tab portion of the dialog
box must be completed as shown in the following window:
Set the IP address value to the module’s Ethernet IP address. You must press
the "Insert" key to add the second line for ControlLogix Backplane and set the
slot number to zero.