RLXIC-EH Intelligent Cellular Configuration Commands
RadioLinx Intelligent Cellular Ethernet Gateway for HSUPA (3G GSM) Networks User Manual
Page 98 of 111 ProSoft Technology, Inc.
May 29, 2009
*DBGETHLVL=n
Sets the logging level for the Ethernet port.
n=0 : No logging
n=1 : Log errors: invalid/corrupt packets, etc.
n=2 : Log the header of all received packets. Note that this can quickly
exhaust available space for the event log.
*DBGDHCPLVL=n
Enable or disable internal DHCP logging.
n=0 : No logging
n=1 : Log DHCP events.
NAI = [name]
Enter the user name of your account (NAI). The user name is usually expressed
as an email address with phone number of the account (example,
[email protected]). This information should be provided by your carrier. You
may not need this step.
name=provided by carrier
PHA = d.d.d.d
Set the IP address of the primary home agent.
d.d.d.d=IP Address
SHA = d.d.d.d
Set the IP address of the secondary home agent.
d.d.d.d=IP Address
MHSS = n
Set the home agent shared secret key.
n=key
MASS = n
Set the AAA shared secret key.
n= AAA Key